Filter Plates: Choosing a Membrane and a Pore Size
By Arctic White Team. Part of the Learning Center.
The short answer
Choose the membrane for the chemistry and the sample, then the pore size for what has to pass and what has to stay, then the well volume for your sample size. Polypropylene (PP) is the general purpose membrane, PVDF is the low protein binding choice, glass fiber (GF) handles crude, high particulate samples, polyethylene (PE) frits support solid phase extraction beds, and PES covers fast aqueous filtration. Most routine work runs at 0.45 µm.
Membranes and what each is for
| Membrane | Pore sizes we list | Choose it when |
|---|---|---|
| Polypropylene (PP) | 0.45 µm | General filtration, solvent resistant, the default |
| PVDF, hydrophilic | 0.2 µm, 0.45 µm | Protein work, where low binding protects recovery |
| Glass fiber (GF) | 0.7 µm, 1.0 µm, 1.2 µm | Crude samples and high particulate loads |
| PE frit (incl. UHMW PE) | 25 µm, 65 µm | Solid phase extraction, holding a sorbent bed |
| PES | 0.45 µm and 10 kDa grades | Fast aqueous filtration and molecular weight cut-off work |
The media list is the Arctic White filter plate range. Combined and stacked configurations, for example a PE frit over glass fiber, are listed on the product pages and in filter plates.
Pore size: the working rule
0.45 µm is the routine clarification size: it removes particulates and protects downstream instruments. 0.2 µm is the finer grade, used where smaller particles or a sterile filtrate matter. Frits at 25 µm and above are not clarifying anything; they are a floor that holds a bed or a resin while liquid passes. If a plate clogs, the fix is usually a coarser membrane or a glass fiber pre-filter layer, not more vacuum.
Volume and drip director
Our 96 well filter plates run 300 µL, 400 µL, 800 µL and 2 mL on the same ANSI/SLAS footprint, and the volume choice is worked through in which filter plate volume? The 2 mL PP plate, AWFP-F20061, carries a 0.45 µm PP membrane in square wells with an 8.23 mm opening, a long drip director, and lists at $963.00 per case of 25, checked 2026-11-20. A long drip director aims the filtrate into the receiver well below it; a short drip director suits plates that sit closer to the receiver. Match the director to your manifold and receiver plate stack.
FAQ
What pore size should I use for routine sample clarification?
0.45 µm is the routine size. It removes the particulates that clog instruments and columns. Use 0.2 µm where finer particles or a sterile filtrate matter, and a glass fiber grade where the sample is crude enough to blind a 0.45 µm membrane.
Which membrane binds the least protein?
Hydrophilic PVDF is the low protein binding choice in our range, listed at 0.2 µm and 0.45 µm. If recovery of a protein sample matters, start there and verify with your own sample.
What is a PE frit filter plate for?
A polyethylene frit, 25 µm or 65 µm, is a porous floor rather than a fine membrane. It holds a sorbent or resin bed in the well while liquid passes, which is the basis of solid phase extraction in plate format.
Why does my filter plate clog?
Usually the membrane is finer than the sample. Crude or high particulate samples blind a 0.45 µm membrane quickly. Move to a glass fiber grade, or a stacked plate with a glass fiber layer over the membrane, before increasing vacuum or pressure.
Sources
Product page for AWFP-F20061 and the filter plate range on arcticsci.com, checked 2026-11-20. Membrane and pore size list from the Arctic White filter plate range.