Filter Plates: Choosing a Membrane and a Pore Size

By Arctic White Team. Part of the Learning Center.

The short answer

Choose the membrane for the chemistry and the sample, then the pore size for what has to pass and what has to stay, then the well volume for your sample size. Polypropylene (PP) is the general purpose membrane, PVDF is the low protein binding choice, glass fiber (GF) handles crude, high particulate samples, polyethylene (PE) frits support solid phase extraction beds, and PES covers fast aqueous filtration. Most routine work runs at 0.45 µm.

Membranes and what each is for

MembranePore sizes we listChoose it when
Polypropylene (PP)0.45 µmGeneral filtration, solvent resistant, the default
PVDF, hydrophilic0.2 µm, 0.45 µmProtein work, where low binding protects recovery
Glass fiber (GF)0.7 µm, 1.0 µm, 1.2 µmCrude samples and high particulate loads
PE frit (incl. UHMW PE)25 µm, 65 µmSolid phase extraction, holding a sorbent bed
PES0.45 µm and 10 kDa gradesFast aqueous filtration and molecular weight cut-off work

The media list is the Arctic White filter plate range. Combined and stacked configurations, for example a PE frit over glass fiber, are listed on the product pages and in filter plates.

Pore size: the working rule

0.45 µm is the routine clarification size: it removes particulates and protects downstream instruments. 0.2 µm is the finer grade, used where smaller particles or a sterile filtrate matter. Frits at 25 µm and above are not clarifying anything; they are a floor that holds a bed or a resin while liquid passes. If a plate clogs, the fix is usually a coarser membrane or a glass fiber pre-filter layer, not more vacuum.

Volume and drip director

Our 96 well filter plates run 300 µL, 400 µL, 800 µL and 2 mL on the same ANSI/SLAS footprint, and the volume choice is worked through in which filter plate volume? The 2 mL PP plate, AWFP-F20061, carries a 0.45 µm PP membrane in square wells with an 8.23 mm opening, a long drip director, and lists at $963.00 per case of 25, checked 2026-11-20. A long drip director aims the filtrate into the receiver well below it; a short drip director suits plates that sit closer to the receiver. Match the director to your manifold and receiver plate stack.

FAQ

What pore size should I use for routine sample clarification?

0.45 µm is the routine size. It removes the particulates that clog instruments and columns. Use 0.2 µm where finer particles or a sterile filtrate matter, and a glass fiber grade where the sample is crude enough to blind a 0.45 µm membrane.

Which membrane binds the least protein?

Hydrophilic PVDF is the low protein binding choice in our range, listed at 0.2 µm and 0.45 µm. If recovery of a protein sample matters, start there and verify with your own sample.

What is a PE frit filter plate for?

A polyethylene frit, 25 µm or 65 µm, is a porous floor rather than a fine membrane. It holds a sorbent or resin bed in the well while liquid passes, which is the basis of solid phase extraction in plate format.

Why does my filter plate clog?

Usually the membrane is finer than the sample. Crude or high particulate samples blind a 0.45 µm membrane quickly. Move to a glass fiber grade, or a stacked plate with a glass fiber layer over the membrane, before increasing vacuum or pressure.