Why Edge Wells Evaporate, and the Seal That Stops It
By Arctic White Team. Part of the Learning Center.
The short answer
The wells around the edge of a plate lose water faster than the wells in the middle. Over an incubation or a storage period, the edge wells end up with less volume and a higher concentration than the center, and the assay reads that difference as if it were biology. The fixes are to protect the perimeter or to seal every well on its own. Skipping the edge wells works too, and on a 96 well plate it costs 36 of the 96 wells.
Why the edge loses first
Evaporation stops when the air above a well is saturated. Center wells share their air with dozens of neighboring wells, so the local humidity above them builds and the loss slows. A perimeter well has neighbors on two or three sides only; on the other side is the plate wall, the incubator air and any draft or temperature gradient in the chamber, all of which keep the air above the edge drier. The edge well keeps evaporating into that drier air. The smaller the fill volume, the sooner the loss becomes a large share of the well: a few microliters out of a 300 µL storage well is noise, and the same loss out of a 35 µL working volume in a low volume 384 well is a changed concentration.
What it does to results
Evaporation removes water, not sample. What is left behind is more concentrated: more compound, more salt, more buffer, in less liquid. In an assay that reads as stronger signal at the edges, the pattern sometimes called the edge effect. In storage it is quieter and worse: the plate comes out of the freezer with the outer wells at a different concentration from the inner ones, and nothing on the plate says so. Either way the plate is reporting its geometry instead of your experiment.
The workarounds, and what each one costs
Leave the edge wells empty. The standard workaround, and it works because the samples never sit in the fast wells. On a 96 well plate the perimeter is 36 wells, 37.5% of the plate, spent on not running samples. On a 384 the perimeter is 76 of 384, about 20%.
Fill the edge wells with water or blank medium. The sacrificial wells humidify the perimeter and take the loss themselves. The plate keeps its sample wells, at the cost of the blanks and the pipetting time.
Control the chamber. A humidified incubator and minimal door opening slow the loss for every well. It helps, and it depends on equipment and habits outside the plate.
Seal the plate. A seal closes the air space above each well, so there is nothing for the well to evaporate into. This is the only fix that travels with the plate, into the incubator, the reader queue and the freezer alike.
A plug per well, or one sheet over all of them
An adhesive film seals a plate with one sheet and one layer of adhesive. The perimeter is where that seal is weakest: the film ends there, handling starts there, and cold makes adhesives less willing to hold. A sealing mat seals differently. Each well gets its own plug, pressed into the well opening, so the edge wells are closed with the same mechanical seal as the center wells, and the seal does not depend on an adhesive staying flexible at -80 °C. A mat also comes off and goes back on, and a pre-scored mat such as AWSM-1002RBX lets a needle sample one well without opening the rest of the plate. The full comparison, including optical reads where film wins, is in Sealing Mat or Adhesive Film?
Check your own plate
Fill a plate with water or buffer at your working volume, seal it the way you seal samples, and weigh it before and after your usual incubation or storage period. Then read a dye, or weigh edge and center wells separately. If the perimeter is losing more than the center, the pattern will be visible in one run, and you will know whether the fix you need is the chamber, the blanks or the seal.
FAQ
Why do edge wells evaporate faster?
The perimeter wells sit next to the plate's outer wall, where air moves and temperature is least even, so the air above them stays drier and keeps taking up water. Center wells are surrounded by other wells, and the shared humidity above them slows loss.
How many wells are on the edge of a 96 well plate?
36 of the 96. Leaving the perimeter empty, a common workaround, gives up 37.5% of the plate before the experiment starts.
Does a sealing mat help with evaporation?
A mat plugs each well individually, so every well, edge wells included, is closed on its own. An adhesive film closes the plate with one sheet and one adhesive layer, and the seal at the perimeter is where films lift first. For storage, a mat rated for your temperature is the repeatable seal.
How can I check whether evaporation is affecting my assay?
Fill a plate with water or buffer at your working volume, seal it the way you seal samples, and weigh it before and after your usual incubation or storage. Weighing individual edge and center wells, or reading a dye in them, shows where the loss sits.
Sources
Product pages for AWSM-1002RB and AWSM-1002RBX on arcticsci.com, checked 2026-11-20, and the Learning Center guide Sealing Mat or Adhesive Film? Perimeter counts are the geometry of the 8 x 12 and 16 x 24 well grids.